We earn a commission if you buy through our links, at no extra cost to you.
Air Compressor for Sprinkler Blowout: What to Buy
Which air compressor can blow out a home sprinkler system? Size it from zone GPM, check CFM at 40 PSI, keep pressure under pipe limits, and compare four models.
At a glance
Size the compressor from your largest zone: GPM divided by 7.5 gives the CFM needed, checked at 40 PSI. The California Air Tools 20020 lists 6.40 CFM at 40 PSI, and the Makita MAC5200 lists 6.9. The Makita MAC2400 suits smaller zones, and the 8010 suits very small ones.


Every fall in cold-winter states, homeowners with in-ground irrigation face the same chore: push the water out of the pipes before the first hard freeze. The tool for the job is compressed air, and the question that decides whether your compressor can do it is not tank size or horsepower. It is airflow. This guide shows how to size a compressor for a sprinkler blowout from your own zone data, what pressure limits to respect, and which compressors from our lineup fit which kind of system.
One honest caveat first. Irrigation manufacturers treat this as a job for licensed contractors, and the contractor-grade compressors they use are far larger than anything in a home garage. A consumer compressor can work on a system with small zones, and that is the case this guide covers. If your zones are large or you are unsure, hire a pro or rent a bigger machine. Specs and procedures below come from Colorado State University Extension, Hunter Industries and the compressor makers, as listed under Sources.
How Much Air Does a Sprinkler Blowout Need?
Colorado State University Extension and Hunter Industries give the same rule of thumb: take the total GPM of your largest zone and divide by 7.5. The result is the CFM you need at the point where the compressor connects to the irrigation system. Colorado State’s own example is a 20 GPM zone, which works out to about 2.7 CFM at 30 psi.
Here is what that arithmetic looks like for a few zone sizes:
| Largest zone | CFM needed (GPM ÷ 7.5) |
|---|---|
| 15 GPM | 2.0 |
| 22 GPM | 2.9 |
| 30 GPM | 4.0 |
| 45 GPM | 6.0 |
You find zone GPM on your irrigation plan, or by adding up the GPM ratings of the nozzles in the zone. Colorado State adds a practical test: if the sprinkler heads stay popped up while air keeps flowing, the compressor is the right size. It also notes that an undersized compressor takes longer and works harder, while an oversized one can pressurize the system too quickly, which a regulator on the outlet can handle.
Read CFM at 40 PSI, Not 90 PSI
Air tool buyers compare CFM at 90 PSI. A sprinkler blowout runs at much lower pressure, so the CFM at 40 PSI is the relevant number, and it is always a little higher than the 90 PSI figure. The makers in our lineup list both:
- California Air Tools 8010: 3.10 CFM at 40 PSI and 2.20 CFM at 90 PSI.
- Makita MAC2400: 4.8 CFM at 40 PSI and 4.2 CFM at 90 PSI.
- California Air Tools 20020: 6.40 CFM at 40 PSI and 5.30 CFM at 90 PSI.
- Makita MAC5200: 6.9 CFM at 40 PSI and 6.5 CFM at 90 PSI.
Dividing by the 7.5 formula in reverse, 3.10 CFM matches a zone of about 23 GPM, 4.8 CFM about 36 GPM, 6.40 CFM about 48 GPM and 6.9 CFM about 52 GPM. Treat these as ceilings on paper, not guarantees. A maker’s rating is measured at the compressor, the formula asks for airflow at the connection, and hoses, fittings and the length of the run all take a share. Leave yourself a margin.
Pressure Limits You Must Respect
Colorado State University Extension says to keep the compressor between 40 and 80 psi, with 80 psi the maximum for rigid PVC pipe and 50 psi for flexible black polyethylene pipe. Hunter gives the same two limits and adds that blowout pressure should stay below the maximum operating pressure of the lowest-rated component in the zone. Excess pressure can blow nozzles off, so check their ratings.
All four compressors below can build far more pressure than a polyethylene system tolerates, so a regulator and a gauge on the outlet are part of the setup, not extras. Set the pressure before you open the valve to the system.
How a Blowout Works
The steps below follow Hunter’s and Colorado State’s instructions. Read the full pages under Sources before you start.
- Shut off the irrigation water supply.
- Connect the compressor hose to the system through a quick coupler, hose bib or similar fitting located after the backflow device. Hunter says compressed air should not be blown through any backflow device, and Colorado State warns that PVB and RP backflow devices have rubber seals that can melt.
- Keep the compressor’s valve closed while you attach the hose, then open it slowly so air enters gradually.
- Start with the zone that is highest in elevation and farthest from the compressor, and work toward the closest.
- Run each zone until no water leaves the heads, which Hunter says takes about two minutes or more. Use two or three short cycles per zone rather than one long one.
- Stop once a zone is dry. Air moving through dry pipe creates friction and heat that can damage it, and Hunter says never to run the compressor without at least one control valve open.
- Disconnect the compressor and release any pressure left in the system.
Hunter also says not to fill the tank and then release the high-pressure air into the mainline to make up for a compressor’s lack of CFM. That is why airflow, not tank size, is the number to buy on. Remove flow sensors first, and do not leave the compressor unattended.
Safety: Hunter’s warning is blunt: wear ANSI-approved eye protection, and do not stand over any pipes, sprinklers or valves while the system is under air pressure. Compressed air can cause serious injury, including eye injury from flying debris.
Our Picks for a Sprinkler Blowout
California Air Tools 20020: Largest Tank, Quiet for the Size

For a typical home system with mid-size zones: 6.40 CFM at 40 PSI from a 20-gallon oil-free tank, rated at 70 dB.
On paper it handles zones up to roughly 48 GPM. The maker lists a 70/30 duty cycle with a maximum continuous run of 60 minutes depending on pressure and CFM, which is more than enough for a series of two-minute zone cycles with rests between. There is no oil to check, a plus for a machine you only start up once a year. The trade-offs are about 115 lbs of weight and a 14-amp draw that wants a dedicated 120V circuit. Read the California Air Tools 20020 profile.
Makita MAC5200: The Airflow Pick

For larger zones: 6.9 CFM at 40 PSI, the most airflow in our lineup, from a cast-iron Big Bore pump with wheels and a roll cage.
It has the highest airflow rating we list, so it matches the largest zones a home compressor can plausibly serve. Its 5.2-gallon tank is small, which is fine here because the pump runs while the zone blows out. It is oil-lubricated, so check the sight glass before its yearly run. Its noise is not listed by Makita. See the Makita MAC5200 profile.
Makita MAC2400: Lighter, for Mid-Size Zones

For moderate zones when weight matters: 4.8 CFM at 40 PSI in a 77 lb Big Bore unit carried by a roll-bar handle.
The formula puts its ceiling at a zone of about 36 GPM. It is a fit if your plan shows modest zones and you also want a compressor for nailers and garage jobs. It is carried, not wheeled. See the Makita MAC2400 profile.
California Air Tools 8010: Only for Very Small Zones

For small zones only: 3.10 CFM at 40 PSI, an 8-gallon oil-free tank, 60 dB and 48 lbs on wheels.
It is the lightest and quietest option, but 3.10 CFM matches a zone of about 23 GPM at best. Choose it only if the arithmetic on your own zones lands well below that. Otherwise step up to a larger model. See the California Air Tools 8010 profile.
Which Zone Size Matches Which Compressor
| Your largest zone | Compressor to consider |
|---|---|
| Up to about 20 GPM | California Air Tools 8010 |
| Up to about 30 GPM | Makita MAC2400 |
| Up to about 45 GPM | California Air Tools 20020 |
| Up to about 50 GPM | Makita MAC5200 |
These are the formula’s ceilings with a small margin removed. If your largest zone is above about 50 GPM, a home compressor is the wrong tool, and a rental or a contractor is the better route.
Do Not Go Smaller Than Your Zones Allow
Small pancake compressors are great for tires and trim nailers, but their airflow is limited. The CRAFTSMAN CMEC6150K lists 2.6 SCFM at 90 PSI and the California Air Tools 1P1060S lists 1.60 CFM at 40 PSI. Those figures only cover very small zones, and many home systems have zones that flow more. If your numbers do not clear the formula, a larger machine or a rental is a better choice than hoping.
Beyond the Blowout: A Compressor You Will Use All Year
A compressor that sits unused for 11 months is a poor value. The units above also handle nailers, tire inflation and garage work, and our air compressor ranking for 2026 compares all of them side by side. If most of your use will be in the garage, our home garage compressor guide covers circuits, noise and oil upkeep. For small trim work, see our nail gun compressor guide. Draining the tank after each use also applies here: moisture collects in any air tank, so open the drain after the blowout and store the compressor dry.
Sources
- Colorado State University Extension: Home Sprinkler Systems, Preparing Your Sprinkler System for Winter
- Hunter Industries: Winterizing Your Irrigation System
- California Air Tools 20020 official product page
- California Air Tools 8010 official product page
- Makita MAC5200 official product page
- Makita MAC2400 official product page
- CRAFTSMAN CMEC6150K official product page
- California Air Tools 1P1060S official product page
Frequently asked questions
What size air compressor do I need to blow out a sprinkler system?
Both Colorado State University Extension and Hunter Industries give the same rule of thumb: take the gallons per minute (GPM) of your largest zone and divide by 7.5 to get the CFM needed at the connection point. A 30 GPM zone, for example, needs about 4 CFM. Check the CFM rating your compressor lists at 40 PSI, because blowouts run at low pressure.
What PSI should I use to blow out sprinklers?
Colorado State University Extension says to stay between 40 and 80 psi, with 80 psi the maximum for rigid PVC pipe and 50 psi for flexible black polyethylene pipe. Hunter gives the same two limits and adds that pressure should stay below the lowest-rated component in the zone. Use a regulator and a gauge, and when in doubt start low.
Can I use a small pancake compressor for a sprinkler blowout?
Only if your zones are small. A pancake compressor lists 2 to 3 CFM at 90 PSI, which by the 7.5 formula supports zones of roughly 15 to 22 GPM, and less airflow than that at higher pressure. Many home zones flow more. Check your zone GPM first, and do not try to make up for low airflow by filling the tank and dumping it into the line, which Hunter warns against.
Is a 20-gallon compressor enough for a home irrigation system?
It can be, if your largest zone fits the airflow. The California Air Tools 20020 lists 6.40 CFM at 40 PSI, which the formula matches to a zone of about 48 GPM. The tank helps the pump rest, but airflow is what clears the water, so compare zone GPM with CFM rather than gallons.
Should I blow out my sprinklers myself or hire a pro?
Hunter says that because of the potential dangers, it is best to call a professional, and that a qualified licensed contractor should do the blowout. Compressed air can throw debris and cause serious eye injury. If you do it yourself, wear ANSI-approved eye protection, never stand over pipes, valves or heads, and never leave the compressor unattended.
Can I rent a compressor instead of buying one?
Hunter notes that blowout-capable compressors can be rented from a local equipment rental yard. Renting makes sense for a large system with high-flow zones. Buying makes sense if your zones are small, or if you will also use the compressor for tires, nailers and other garage jobs.